The 3D view can now be controlled using the cursor and page up / page down keys. (VSP 000056)
The remove reflections function was rounding of the top of the product if a small spike existed and the remaining points were error values. (VSP 000057)
The 3D view can now be disabled in the Global options window. (VSP 000058)
The post test remove reflections function is now disabled if both the threshold and spike duration are set to 0 (zero). (VSP 000059)
The laser readings are now shown to 2 decimal places in the Utilities Window to aid diagnostics (requires firmware version 60 or later). (VSP 000060)
Added option to freeze columns in the Scan Database viewer. (VSP 000045)
The column order in the Scan Database viewer is now remembered when the window is closed. (VSP 000046)
The old Highlight Missing Files command is now Select Missing Files and the Highlight Missing Files option has changed to a toggle that turns the SavedAs column values red if the file is missing. (VSP 000047)
The size of the last column in the Scan Database Viewer was not being remembered. (VSP 000048)
Fixed a problem with the Highlight Missing Files command in the Scan Database Viewer where it was not highlighting the first missing file of a block of missing files. (VSP 000049)
The order of the columns in the Scan Database Viewer is now remembered when the window is closed and re-opened. (VSP 000050)
The Spike Filter settings for the post scan operation are now setup in the Product Parameters window. (VSP 000051)
The spike filter will now attempt to repair error values received from the scanner (requires firmware version 59 or later). (VSP 000052)
Added Minimum Enclosing Circle function for each slice. This can be displayed on each slice, viewed in the Slice Statistics window and accessed as a standard function in the Custom Results. (VSP 000053)
Added NumSlices as a standard parameter for the Custom Results formula. (VSP 000054)
The Volume is now displayed with 2 decimal places if it is less than 1ml and 1 decimal place if it is less than 10ml. (VSP 000055)
Updated Direct X to Mar 2009 release. If your 3D view does not work then install the latest DirectX drivers from our web site. http://textureanalyser.co.uk/upgrades/DirectXMar2009Redist.zip
Fixed problem with viewing reports. (VSP 000036)
Added command to save sections as new products so that a scan of multiple products on a skewer can be separated. (VSP 000037)
Added a Demo Mode for continuous scans, mainly for exhibition use. (VSP 000038)
The Scan window now remembers it last position. (VSP 000039)
Calibrating Weight... is now displayed when calibrating the weight. (VSP 000040)
Added support for a Product Properties tab in Explorer for VPD files. (VSP 000043)
Added support for Outlook and Explorer Preview of VPD files. (VSP 000044)
The first step is now fixed at 0.1mm to improve capture of sharp edged products. (VSP 000035)
Fixed a problem with calibration after a test was run at 0.5RPS. (VSP 000034)
Added Slice Stats window. (VSP 000032)
The Width link on the 2D windows was drawing the height guides instead of the width guides. (VSP 000031)
Spin Speed was not working when the decimal point was set to a comma. (VSP 000033)
User measurements can now be added as fields to reports. (VSP 000019)
Fixed problem with User 1 column always being selected in results spreadsheet. (VSP 000020)
Fixed problem where mouse wheel would move the slider bar but not update the active slice in the 2D view. (VSP000021)
Foxed problem with control update in 2D view when window sized slowly. (VSP 000022)
Locked spreadsheet rows from drag and drop as this caused problems with grouping and stats. (VSP 000023)
Improved error detection in custom calculations and now keeps new entry even if it has errors. (VSP 000024)
Added several tools for cleaning up spikes, Remove Spikes, Smooth and Flatten selected data. (VSP 000025)
Added Undo and Redo feature for data changed by new clean up tools. (VSP 000026)
User measurements can now be named. (VSP 000027)
Added option to select rotation speed between slow, standard and fast so scans be be made faster for robust products or slowed down for delicate product. (VSP 000028)
User parameters and calculations can now be exported and imported for easy transfer between products. (VSP 000029)
User measurements can now be deleted when an error exists in the function. (VSP 000015)
User measurements where not being calculated after a new scan (VSP 000016)
The 3D image colour can now be defined in the Product Parameters window. (VSP 000014)
Option to view the results spreadsheet in Excel. (VSP 000013)
User defined parameters and results added. (VSP 000012)
New "Mail to..." command and toolbar button added to email the active document as an attachment. (VSP 000011)
Now drop list added to 2D pot area to quickly select held slice. (VSP 000009)
Slice area and volume now displayed under 2D plot. (VSP 00008)
Volume Yield is now Specific Volume. (VSP 000006)
Fixed problem where column and row headings were not being copied to the clipboard. (VSP 000005)
Slice height and width at the bottom of the 2D plot are now hot spots and when clicked the measurement is added to the user measurements window. (VSP 000004)
Form ratio calculation added. (VSP 000003)
Statistics are now given for the middle slice. (VSP 000002)
User measurements can now be added to the results spreadsheet. (VSP 000001)